208896- SYSTEM, RO, LP-700, AXEON

Part #: 208896 / 210264
Login / Register

AXEON® LP– Series Reverse Osmosis Systems are engineered in response to the need within the light commercial markets. The LP–Series systems provide a cost-effective solution for customers and are easy to install and maintain. These systems are designed to be wall mounted or free-standing and feature a 5-Micron Sediment and 10-Micron Carbon Pre-Filters, Slim Line Filter Housings and AXEON 500 GPD membranes and membrane housings.

AXEON LP– Series Reverse Osmosis Systems are available in models ranging from 350 to 700 gallons per day (GPD), at a line pressure of 70 psi. The LP– 500 model is available with a pump to deliver 500 GPD.

The LP-Series models can also be upgraded with an optional cover that includes pressure gauges and a dual TDS meter.

Features:

  • Cover with Glycerin-Filled Pressure Gauges (Post-Filter, Operational Pressure, and Permeate Pressure)
  • DM-2 Dual TDS Monitor
  • TE-3012-500 Membrane Element
  • 3012 Membrane Housing
  • 2.5" x 20" 5-Micron Sediment Pre-Filter
  • 2.5" x 20" 10-Micron Carbon Block Pre-Filter and Post Filter
  • 20" Slim Line Cartridge Housings
  • Automatic Shut Off Valve (LP-350 and LP-700)
  • Push/Pull Fittings with Locking Safety Clip
  • Auto Flush Valve (LP-500 only)

        Specifications:

        • Model: LP-700
        • AXEON Part Number: 208896
        • Capacity (gpd): 700


        Design:

        • Configuration: Single Pass
        • Feedwater Source: TDS <500 ppm
        • Standard Recovery Rate %: 38


        Flow Rates:

        • Permeate Flow (gpm): 0.49
        • Minimum Feed Flow (gpm): 1.33


        Connections:

        • Feed (in): 3/8" QC
        • Permeate (in): 3/8" QC
        • Concentrate (in): 3/8" QC


        Membranes:

        • Membrane(s) Per Vessel: 1
        • Membrane Quantity: 2
        • Membrane Size: 3012
        • Nominal Salt Rejection %: 98


        Vessels:

        • Vessel Array: 2 (Parallel)
        • Vessel Quantity: 2


        Pumps:

        • Pump Type: N/A
        • Motor HP: N/A


        System Electrical:

        • Standard Voltage + Amp Draw: N/A


        Operating Limits:

        • Maximum Feed Temperature (°F / °C):  85 / 29
        • Minimum Feed Temperature (°F / °C):  40 / 4
        • Maximum Ambient Temperature (°F / °C): 120 / 49
        • Minimum Ambient Temperature (°F / °C): 40 / 4
        • Maximum Feed Pressure (psi / bar): 90 / 6
        • Minimum Feed Pressure (psi / bar): 70 / 5
        • Maximum Operating Pressure (psi / bar): 90 / 6
        • Maximum Feed Silt Density Index (SDI): <1
        • Maximum Turbidity (NTU): 1
        • Maximum Free Chlorine (ppm): 0
        • Maximum TDS (ppm): 500
        • Maximum Hardness (gpg): 1
        • Maximum pH (Continuous): 10
        • Minimum pH (Continuous): 4
        • Maximum pH (Cleaning 30 Minutes): 12
        • Minimum pH (Cleaning 30 Minutes): 2

         

        Warranty:

        • 1-Year Warranty

        Q&A

        Have a Question?

        Be the first to ask a question about this.

        Ask a Question

        NEED HELP?

        Need help finding a replacement part? Fill out our part request form and someone will get back to you shortly. Can’t wait? You can also call our customer support line.